How do I troubleshoot Kenmore 796 Model Front-Load Washer that has a Inlet Water Supply Error?

The initial expected water level is not reached in 8 minutes or the final preset water level is not reached in 25 minutes. The water supply faucets for the washer need to be open. The inlet water valves should be checked. The inlet water valve assembly needs to be replaced if the valves are malfunctioning. The main electronic control board should be replaced if the water valves are ok.