How do I troubleshoot Kenmore Hybrid Dryer that is displaying tE6 error code?

Check the compressor outlet for thermistor wiring when you unplug the dryer. Attach the loose wires. If the wire harness is damaged, you need to replace it. Check the compressor outlet thermistor's resistance. At room temperature it should measure about 10,000 ohms. You should replace the thermistor if it's malfunctioning. The compressor outlet thermistor and wiring need to be replaced.